top of page
Search

Mowbry Mountain Passive House

  • Writer: Happy Yates Baker
    Happy Yates Baker
  • Jul 23, 2024
  • 1 min read

Updated: Sep 24, 2024



Project Metrics:

  • Two Story Residence w/ Full Basement

  • Passive Solar Design –Zero Energy Ready

  • Designed to meet PHIUS Standards / Not Certified

  • 4000 sf Conditioned Space (Including Basement). 3 BR / 2  Bath

  • Foundation Wall: Conc. w/ Exterior Insulation R-20

  • Exterior Walls: 4.5” Polyurethane SIPS R-33

  • Roof: 5.5” Polyurethane SIPS R-40

  • Windows: Intus Triple Glazed: U-Factor 0.14

  • Doors: Intus Triple Glazed: U-Factor 0.14

  • Basement Door: Therma-Tru U-Factor: 0.28Insulated Concrete Basement Floor w/ Hydronic Radiant

  • 8/12 Pitch Vaulted Ceiling

  • (2) 1 Ton Mini-Split HVAC Units

  • Whole House ERV

  • HERS Index : 38

  • Energy Cost Analysis:

    • Annual $824.25

    • Average $68.00 / Month

    • 1.696 kWh / sf / yr

    • $0.206 / sf / yr








 
 
 